Air & Solid-Insulated RMU

XGN□-12/24 Indoor Air-Insulated Ring Main Unit

Box-type fixed metal-enclosed RMU for 12/24 kV ring networks and terminal distribution — GB 3906 / IEC 298 compliant with full five-prevention interlocking; SF6 maintenance-free load switch inside.

Factory-direct supply Worldwide delivery & export documentation 12-month warranty · extended options
  • Compact good-looking cabinets; assembled-row enclosure protection above IP3X
  • Modular upper/lower units for easy installation and maintenance; riveted frame guarantees rigidity
  • Integrated LV compartment for secondary elements, with extensible instrument room for more protection units
  • Pressure-relief duct available; SF6 maintenance-free load switch — economical and reliable
  • Simple operation with complete five-prevention interlocking
Overview

A cleaner, more reliable approach to MV switching

The HP-ELS series replaces SF₆ with environmentally friendly insulating media while keeping the proven safety and performance utilities expect from gas-insulated switchgear.

Product Overview

XGN□-12/24 is a box-type fixed AC metal-enclosed ring main switchgear — a complete AC high-voltage assembly rated 12 kV, 50 Hz. It mainly serves three-phase AC ring networks, terminal distribution grids and industrial loads for power reception, distribution and protection, and is also suitable for installation in box-type substations.

Standards & Interlocking

It complies with GB 3906 (3.6–40.5 kV AC metal-enclosed switchgear and controlgear) and IEC 298, with a complete five-prevention interlock. Upper and lower units are modular; after cabinet combination the enclosure protection exceeds IP3X, and it uses an SF₆-insulated maintenance-free load switch — economical, reliable and easy to operate.

Specifications

Technical specifications

Headline ratings at a glance, followed by the full technical data sheet. Exact values are confirmed per project configuration.

Rated voltage12 / 24kV
Frequency50Hz
Assembled-row protection> IP3X
Load switchSF6 · maintenance-free
ParameterValue
Rated voltage12 kV
Rated frequency50 Hz
Power-frequency withstand (phase/earth/break)42 / 48 kV (1 min)
Lightning impulse withstand75 / 85 kV
Enclosure protection (combined)> IP3X
Load switchSF₆-insulated, maintenance-free
InterlockingComplete five-prevention
Altitude≤ 1000 m
Ambient temperature-35℃ to +45℃
Seismic capacityGrade 8
StandardsGB 3906 / IEC 298 / GB/T 11022
Model Meaning

Reading the model designation

X Box type
G Fixed type
N Indoor type
15 Design serial number
12/24 Voltage class kV

Generated automatically from each product's model code.

Dimensions

Overall dimensions

Cabinet height, width and depth options. Selection depends on cable type and incoming / outgoing configuration.

ItemDimensions (mm)Scope of application
Height H1400Single-core cables
Height H1600Single-core cables
Height H1800Three-core cables
Width W375 / 500 / 750Incoming / outgoing
Depth D918Standard

Need help selecting for your project?

Send us your single-line diagram or requirements — our engineers will provide configuration, full specifications and export documentation.

Request a quote
Factory-direct supply Worldwide delivery Export documentation