Gas-Insulated RMU

HP-ELS Eco-Gas Insulated Ring Main Unit

Vacuum-interruption RMU with eco-gas main insulation at zero/micro positive pressure (≤0.02 MPa) — unencapsulated main circuit, built-in data acquisition and online monitoring for smart distribution.

Factory-direct supply Worldwide delivery & export documentation 12-month warranty · extended options
  • Rated voltage · cabinet module (C load switch / V vacuum breaker / F load-switch + fuse combination) · operati
Overview

A cleaner, more reliable approach to MV switching

The HP-ELS series replaces SF₆ with environmentally friendly insulating media while keeping the proven safety and performance utilities expect from gas-insulated switchgear.

Product Overview

The HP-ELS-12/24/40.5 eco-friendly gas-insulated ring main unit uses vacuum interrupters for arc extinction, with eco-friendly gas as the main insulating medium plus a small number of solid insulating supports; the main circuit is completely unencapsulated. Under normal operation it runs at zero gauge or slight positive pressure (gas-tank pressure ≤0.02 MPa), and its phase-to-earth and phase-to-phase insulation meets air-insulation requirements at zero gauge pressure.

Intelligence & Applications

Integrating data acquisition and control, data processing and storage, and online monitoring with advanced analysis, the product enables online intelligent monitoring and management of the distribution network — delivering remote monitoring, control and management to meet grid optimisation, power-consumption safety, energy management and energy-saving needs. It is widely used in intelligent distribution scenarios such as transport hubs, factories, hospitals, schools, buildings, residential communities and commercial offices.

Specifications

Technical specifications

Headline ratings at a glance, followed by the full technical data sheet. Exact values are confirmed per project configuration.

Rated voltage12kV
1 min power-frequency withstand42 / 48kV
Lightning impulse withstand75 / 85kV
Rated current (C / F / V)630 / 125 / 630A
ParameterValue
Rated voltage12 kV
1 min power-frequency withstand42 / 48 kV
Lightning impulse withstand75 / 85 kV
Rated current (C / F / V)630 / 125 / 630 A
Closed-loop breaking current (C)630 A
Cable-charging breaking current (C)135 A
Earth-fault breaking current (C)200 A
Short-circuit breaking current (F / V)31.5 / 25 kA
Rated transfer current (F)1500 A
Max fuse rating (F)125 A
Model Meaning

Reading the model designation

HP-ELS Product model
Rated voltage kV
Cabinet module: C Load / V VCB / F Load-Fuse
Operating mode
Rated current A
Breaking current kA

Generated automatically from each product's model code.

Dimensions

Overall dimensions

Cabinet height, width and depth options. Selection depends on cable type and incoming / outgoing configuration.

ItemDimensions (mm)Scope of application
1 Circuit420 / 380 / 420Per drawing A/B/C (mm)
2 Circuits808 / 768 / 808Per drawing A/B/C (mm)
3 Circuits1196 / 1156 / 1196Per drawing A/B/C (mm)
4 Circuits1584 / 1544 / 1584Per drawing A/B/C (mm)