LV Switchgear

GGD Fixed LV Distribution Cabinet

Classic fixed-type 380 V switchboard up to 3150 A with 129 main-circuit schemes in 298 specs (GGD1/2/3 at 15/30/50 kA) — high breaking capacity, strong dynamic-thermal stability, flexible assembly.

Factory-direct supply Worldwide delivery & export documentation 12-month warranty · extended options
  • GB/T 7251.2-2023 Low-voltage switchgear and controlgear assemblies — Part 2
  • Designation: power cabinet · fixed mounting & wiring · AC LV distribution · design serial (1 = 15 kA, 2 = 30 k
Overview

A cleaner, more reliable approach to MV switching

The HP-ELS series replaces SF₆ with environmentally friendly insulating media while keeping the proven safety and performance utilities expect from gas-insulated switchgear.

Product Overview

The GGD AC low-voltage distribution cabinet suits power plants, substations and industrial/mining users, for AC 50 Hz distribution systems rated 380 V and up to 3150 A — for the energy conversion, distribution and control of power, lighting and distribution equipment.

Features

Designed on principles of safety, economy, rationality and reliability, it provides high breaking capacity, good dynamic and thermal stability, flexible electrical schemes, convenient assembly, a complete series, strong practicality, a novel structure and a high protection grade — an upgraded replacement for low-voltage switchgear assemblies. It complies with GB/T 7251.2-2023.

Specifications

Technical specifications

Headline ratings at a glance, followed by the full technical data sheet. Exact values are confirmed per project configuration.

GGD1 — rated current A/B/C1000 / 630 / 400A
GGD1 — breaking / withstand / peak15 / 15 / 30kA
GGD2 — rated current A/B/C1600 / 1000 / 600 A
GGD2 — breaking / withstand / peak30 / 30 / 63kA
ParameterValue
GGD1 — rated current A/B/C1000 / 630 / 400 A
GGD1 — breaking / withstand / peak15 / 15 / 30 kA
GGD2 — rated current A/B/C1600 / 1000 / 600 A
GGD2 — breaking / withstand / peak30 / 30 / 63 kA
GGD3 — rated current A/B/C3150 / 2500 / 2000 A
GGD3 — breaking / withstand / peak50 / 50 / 105 kA
Model Meaning

Reading the model designation

G Power distribution cabinet
G Fixed installation and wiring
D AC low-voltage distribution cabinet
Design serial (1=15kA / 2=30kA / 3=50kA breaking)
Main circuit scheme code
Auxiliary circuit scheme code

Generated automatically from each product's model code.

Dimensions

Overall dimensions

Cabinet height, width and depth options. Selection depends on cable type and incoming / outgoing configuration.

ItemDimensions (mm)Scope of application
Width W600 / 800 / 1000 / 1200By model (GGD06/08/10/12)
Depth D600 / 800By model